3D-model
The laboratory consists of the following equipment:
NTC-08.10 “House power connection and room distribution”.
NTC-08.11 “Concealed indoor wiring”.
NTC-08.12 “Multimedia indoor wiring”.
NTC-08.16 “3-phase motor control with magnetic starters”.
NTC-08.17 “3-phase motor control with a controller”.
NTC-08.18 “3-phase motor control with a frequency converter”.
NTC-08.47.1 “Wiring complex”.
NTC-08.10 “House power input and room distribution”.
The training system is designed to carry out experiment in the field of installation and commissioning of electrical installations and safety testing.
Topics studied:
- Home power connection components.
- Installation of components.
- Energy input, energy distribution.
- Electric energy meters.
- Testing and adjustment of installed equipment.
- Checking TN- / TT systems.
- Checking the residual current device.
- Verification of protection devices.
- Checking the direction of a rotating field.
The training system includes:
- junction box;
- buses;
- electricity meter;
- circuit breakers;
- residual current devices;
- surge protection devices;
- surge suppressor;
- 220V sockets;
- key switches;
- spotlights;
- electrical appliances;
- set of wiring tools for working with cable;
- set of electrical tools.
Recommended optional equipment:
- insulation resistance meter;
- multi-channel digital oscilloscope;
- concealed wire finder;
- voltage probe;
- ground resistance meter.
NTC-08.11 “Concealed indoor wiring”.
The training system is designed to get theoretical and practical knowledge in the field of electrical equipment.
Topics studied:
- Types of installation and wiring.
- Installation and assembly of components, cable routing.
- Testing and adjustment of installed equipment.
The training system includes:
- junction box;
- circuit breakers (at least 5);
- residual current devices (at least 2);
- surge protection device;
- DIN transformer (at least 2);
- impulse relay;
- fixtures (not less than 5);
- lamps for fixtures (incandescent, halogen, fluorescent, LED);
- socket for stove;
- 220V sockets (at least 3);
- keyboard switches (at least 3);
- key switch (not less than 3);
- pulse switch (not less than 2);
- regulator (not less than 2);
- electrical appliances;
- mounting materials (cable, terminals);
- multimeter;
- concealed wire finder;
- voltage probe.
Recommended optional equipment:
- set of wiring tools for working with cable;
- set of electrical tools.
NTC-08.12 “Multimedia indoor wiring”.
The training system is designed to carry out experiments in the field of installation and commissioning of home data transmission networks and television.
Topics studied:
- Multimedia cabling components.
- Installation of components.
- The local network.
- Wireless LAN
- Connection of personal computers.
- Installation of coaxial outlets.
- Installation of RJ-45 sockets.
The training system includes:
- junction box;
- circuit breakers;
- residual current devices;
- power supply units;
- access point;
- router
- coaxial sockets;
- 220V sockets;
- RJ-45 sockets;
- DVB-T receiver
- laptop – 2 pcs.
Recommended optional equipment:
- set of wiring tools for working with cable;
- set of electrical tools.
NTC-08.16 “3-phase motor control with magnetic starters”.
The training system is designed to carry out experiments in the field of installation and commissioning of relay-contactor control systems for three-phase electric drives.
Topics studied:
- Protection devices.
- Development of control circuits on magnetic starters.
- Reverse control. Contact blocking.
- Limit switches.
- Time relay.
- Star-delta switching.
- Control of electric motors with two windings.
The training system includes:
- junction box;
- circuit breakers;
- residual current devices;
- buttons and control switches;
- magnetic starters (at least 4);
- pulse contactors (not less than 2);
- star-delta switches;
- time relay (not less than 2);
- limit switches (at least 2);
- multimeter;
- three-phase asynchronous electric motor.
Recommended optional equipment:
- set of wiring tools for working with cable;
- set of electrical tools.
NTC-08.17 “3-phase motor control with a controller”.
The training system is designed to carry out experiments in the field of installation and commissioning of control systems for three-phase electric drives using a controller.
Topics studied:
- Protection devices;
- Development of control schemes.
- Controller programming
The training system includes:
- junction box;
- circuit breakers;
- residual current devices;
- buttons and control switches;
- programmable logic controller;
- magnetic starters (at least 2);
- limit switches (at least 2);
- a laptop;
- three-phase asynchronous electric motor.
Recommended optional equipment:
- multimeter;
- set of wiring tools for working with cable;
- set of electrical tools.
NTC-08.18 “3-phase motor control with a frequency converter”.
The training system is designed to carry out experiments in the field of installation and commissioning of control systems for three-phase electric drives using inverter.
Topics studied:
- Protection devices.
- Development of control schemes.
- Inverter setting.
The training system includes:
- junction box;
- circuit breakers;
- residual current devices;
- buttons and control switches;
- inverter;
- limit switches (at least 2);
- three-phase asynchronous electric motor.
Recommended optional equipment:
- multimeter;
- set of wiring tools for working with cable;
- set of electrical tools.
Training laboratory stand NTC-08.47.1 “Wiring complex”
The training laboratory stand is a double-sided basis. Designed for training students in electrical specialties.
On both sides of the work surface is a built-in electric power supply module for the stand and an aluminum profile frame with a perforated mounting panel mounted on it.
The perforated mounting plate has elongated perforated holes for repeatedly mounting wiring products.
Features of the basic integrated electrical module:
- power supply 1 ~ 220V, 50 Hz, 3 A, 4 pcs.;
- power supply 1 ~ 36V, 50 Hz, 3 A, 4 pcs.;
- power supply 1 ~ 12V, 50 Hz, 3 A, 4 pcs.;
- adjustable power supply 2 … + 30V, 3A, 2 pcs.;
- 0-250V AC voltmeter, 2 pcs.;
- ammeter of alternating current 0-2 A, 2 pcs .;
- diameter of the connected forced draft, 100 mm.
Delivery scope:
- laboratory stand;
- tool kit (for cutting a flat cable, pressing tool, universal knife, side cutters, pliers, a set of screwdrivers).