The measuring system includes pointer instruments for measuring currents of battery, generator, load, generator excitation current and generator speed. Generator excitation current can be supplied from the standard voltage regulator and from the additional regulator of excitation current. The load of the generating unit is adjustable.
Faults introduction unit enables the introduction of different generating unit faults. Faults introduction is realized not from the stand panel as it is done in NTC-15.42, but by means of a PC with special software.
On the bench there are the following acting items:
- accumulator battery;
- generator with integral voltage regulator, motor-driven, with adjustable rotational speed;
- elements of the following ignition systems: contact, induction, contactless with Hall sensor; they include ignition distributors, coils, control units, high-voltage wires and spark plugs.
Spark plugs are installed in a high-pressure chamber with adjustable pressure and a transparent wall for monitoring the process of sparking under different conditions.
An automatic impulse charger is built in the bench for charging the accumulator battery.
The stand is accompanied with a set of teaching materials and technical documentation intended for the teaching staff.